烟气分析仪
____商用燃料燃烧器排烟分析应用
Ref:pFlue2000_IntC
Revision:
IR红外光度计技术,是化学分析行业最高档技术,其优越的长期稳定性、选择性和精确度是电化学探头无法比较的,pSmoke2000基本型产品以红外三参数为主,力求以电化学仪器的价格为广大用户提供目前全世界最高档,高可靠性的烟气分析仪器,
为了解决各种气体传感器之间的互相干扰,北斗星工化采取了综合分析的科学方法,尽量装配全成分分析系统,至少保障装配对主参数干扰较大的气体探测,以实现实时矫正补偿,获得可靠、准确的测试结果,
网上资料
产品资料:http://www.bigdipper-technochem.com/Products/Industry/Smoke&Emissions/pFlue2000_IntC.pdf
烟气分析仪,便携式烟气分析仪,手持式烟气分析仪,便携式烟气分析仪,综合烟气分析仪,德图烟气分析仪,德国德图烟气分析仪,tsi烟气分析仪,国产烟气分析仪,mru烟气分析仪,烟气分析仪价格,国产烟气分析仪,km9106烟气分析仪,二氧化硫烟气分析仪,mru烟气分析仪,testo烟气分析仪,烟气分析仪器,烟气分析系统,
红外光谱分析是最可靠的气体分析技术,红外传感器相比与电化学传感器具有明显的优点(Infra spectroscopy is traditional method for chemical analysis. Relative to electrochemical sensors, IR sensor holds more advantages as following):
1) 寿命长,性能稳定:红外传感器可以使用10年,而电化学传感器理论上可以在空气中保存1-2年(long life and stability. most IR sensors can be used for 5-10 years. But electrochemical sensors only lasts for 1-2 years in air. If the test period lasting longer or being in heavy duty working, it would be exhausted earlier unexpectedly. If working in full scale, most sensor would be exhausted in 400 hours).
2) 红外系统不用化学过滤器,因而稳定性好,可靠性高(Embedded filter or external filter is necessary for electrochemical system. The filter efficiency is changing along using, varying to contaminants, so it is difficult to forecast the compensation. Thus could not get reliable measurements).
3) 高选择性,不象电化学传感器那么严重相互干扰(IR sensor is more specific to objective gases, professional speaking, it is high selective to gases. Generally speaking, there is less of interferences among different gases. For example, EC CO sensors is cross sensitive to HC,H2,CH2CH2, and even H2S,SO2 etc.; EC O2 sensor is sensitive to CO2; EC H2S would be cross interfered by SO2,CO,NO2,NO etc.; SO2 would be cross interfered by CO,NO2,H2,CH2CH2 etc).
4) 近红外激光光谱仪是最新设计的烟气分析仪, 几乎没有互相干扰,主要用于烟气成分比较复杂的工业炉窑气体分析和科学研究工作,参考pFlue4810.
烟气分析仪,便携式烟气分析仪,手持式烟气分析仪,便携式烟气分析仪,综合烟气分析仪,德图烟气分析仪,德国德图烟气分析仪,tsi烟气分析仪,国产烟气分析仪,mru烟气分析仪,烟气分析仪价格,国产烟气分析仪,km9106烟气分析仪,二氧化硫烟气分析仪,mru烟气分析仪,testo烟气分析仪,烟气分析仪器,烟气分析系统,
便携式烟气分析仪,烟气检测仪,在线烟气分析仪,烟气监测仪,便携式烟气分析仪,手持式烟气分析仪,烟气成分分析仪,烟气监测仪,烟道气体检测仪,烟气分析仪,综合烟气分析仪,便携式烟气分析仪,烟气检测仪,在线烟气分析仪,烟气监测仪,便携式烟气分析仪,手持式烟气分析仪,烟气成分分析仪,烟气监测仪,烟道气体检测仪,烟气分析仪,综合烟气分析仪,便携式烟气分析仪,烟气检测仪,在线烟气分析仪,烟气监测仪,便携式烟气分析仪,手持式烟气分析仪,烟气成分分析仪,烟气监测仪,烟道气体检测仪,烟气分析仪,综合烟气分析仪,便携式烟气分析仪,烟气检测仪,在线烟气分析仪,烟气监测仪,便携式烟气分析仪,手持式烟气分析仪,烟气成分分析仪,烟气监测仪,烟道气体检测仪,烟气分析仪,综合烟气分析仪,便携式烟气分析仪,烟气检测仪,在线烟气分析仪,烟气监测仪,便携式烟气分析仪,手持式烟气分析仪,烟气成分分析仪,烟气监测仪,烟道气体检测仪,烟气分析仪,综合烟气分析仪,
用途:主要用于正常燃料燃烧器的烟道气分析,
*特殊工业炉窑烟气分析, 尽量选择 pGas4810-Flue 激光光谱烟气分析仪.
便携式烟气分析仪,烟气检测仪,在线烟气分析仪,烟气监测仪,便携式烟气分析仪,手持式烟气分析仪,烟气成分分析仪,烟气监测仪,烟道气体检测仪,烟气分析仪,综合烟气分析仪,便携式烟气分析仪,烟气检测仪,在线烟气分析仪,烟气监测仪,便携式烟气分析仪,手持式烟气分析仪,烟气成分分析仪,烟气监测仪,烟道气体检测仪,烟气分析仪,综合烟气分析仪,便携式烟气分析仪,烟气检测仪,在线烟气分析仪,烟气监测仪,便携式烟气分析仪,手持式烟气分析仪,烟气成分分析仪,烟气监测仪,烟道气体检测仪,烟气分析仪,综合烟气分析仪,便携式烟气分析仪,烟气检测仪,在线烟气分析仪,烟气监测仪,便携式烟气分析仪,手持式烟气分析仪,烟气成分分析仪,烟气监测仪,烟道气体检测仪,烟气分析仪,综合烟气分析仪,便携式烟气分析仪,烟气检测仪,在线烟气分析仪,烟气监测仪,便携式烟气分析仪,手持式烟气分析仪,烟气成分分析仪,烟气监测仪,烟道气体检测仪,烟气分析仪,综合烟气分析仪,
pFlue2000
烟气分析仪常用基本组合探头技术参数:
气体 |
Gas |
量程 |
准确度 |
重复精度 |
响应 |
方法 |
Flue -Pro |
8s |
6s |
5s |
|
碳氢化合物 |
HC |
0 to 2000 ppm |
+/-3% rel. |
-3ppm/abs or +/-2% rel. |
4.5s |
ND IR |
¤ |
¤ |
¤ |
¤ |
|
|
n-hexane |
2001 to 5000 ppm 5001 to 30000 ppm |
+/- 5% rel. +/-10% rel. |
+/-3% rel. +/- 4% rel. |
|
|
|
|
|
|
|
蒸发污染物 |
VOC |
0 to 30000 ppm |
<+/-10% rel. |
<+/- 4% rel. |
|
|
|
|
|
|
|
一氧化碳 |
CO |
0.00% to 10.00% |
+/-3% rel. |
-200ppm/abs or +/-2% rel. |
4.5s |
RD IR |
¤ |
¤ |
¤ |
¤ |
|
|
|
10.01% to 15.00% |
+/-5% rel. |
+/-3% rel. |
|
|
|
|
|
|
|
二氧化碳 |
CO2 |
0.00% to 16.00% |
+/-3%rel. |
-0.1%/abs or +/-2% rel. |
4.5s |
ND IR |
¤ |
¤ |
¤ |
¤ |
|
|
|
16.01% to 20.00% |
+/-5% rel. |
+/-3% rel. |
|
|
|
|
|
|
|
氧化氮 |
NOx |
0 to 4000/5000 ppm |
+/-4% rel. |
-20ppm/abs or +/-3%rel |
10s |
EC |
¤ |
¤ |
¤ |
¤ |
|
二氧化氮 |
NO2 |
0 t0 200/1000ppm |
+/-2% rel. |
0.5ppm |
60s |
EC |
¤ |
¤ |
|
|
|
二氧化硫 |
SO2 |
0-2,000/5,000ppm |
± 1%rel |
1ppm/abs
or ±3%rel |
40s |
EC |
¤ |
¤ |
¤ |
¤ |
|
硫化氢 |
H2S |
0-50/500ppm |
± 1%rel |
0.1ppm |
30s |
EC |
¤ |
¤ |
|
|
|
氧气 |
O2 |
0.00% to 25.00% |
-0.01% abs. |
-0.1% abs. |
40s |
EC |
¤ |
¤ |
¤ |
|
|
烟度 |
|
Rb 0-10.0 林格曼黑度:0-12(级) |
|
|
透光计 |
¤ |
|
|
|
|
|
烟温 |
|
-40 to |
|
|
热电阻 |
¤ |
|
|
|
|
|
烟尘或粉尘浓度 /颗粒物浓度 |
TSP |
0-1000; 0-5000; 0-20000 mg/M3 |
<5% |
|
|
光散射 |
¤ |
|
|
|
|
过量空气系数 |
a |
0-15 |
<1.5% |
|
|
计算 |
¤ |
¤ |
¤ |
|
|
燃烧效率 |
b |
0-100% |
<2% |
|
|
计算 |
¤ |
¤ |
¤ |
¤ |
|
l 反应时间为T95标准;
l
最低前3项参数组态和技术参数不能改变;
l
用户可以根据需要配置测试参数,
²
电化学检测芯质量保证期 1年,实际使用1-3年,IR探头5年无明显飘逸,寿命10年,
l 增加其它参数,请参考附表,
电气功能及性能:请参考〖BD4/BD5智能变送器/测控器简介〗
机箱封装:
NEMA 1 /IP10; NEMA 4 / IP56
机箱尺寸: 460*350*
供电: 9-24V DC, <1W; 200 V AC,<300W (仅用于带恒温附件的系统)
p-Flue2000 燃烧烟气分析仪
p-Smoke2000-CEMS大气污染物综合排放分析仪
p-Auto2000汽车尾气分析仪
仪器质量保障: 2年
烟气分析仪,便携式烟气分析仪,手持式烟气分析仪,便携式烟气分析仪,综合烟气分析仪,德图烟气分析仪,德国德图烟气分析仪,tsi烟气分析仪,国产烟气分析仪,mru烟气分析仪,烟气分析仪价格,国产烟气分析仪,km9106烟气分析仪,二氧化硫烟气分析仪,mru烟气分析仪,testo烟气分析仪,烟气分析仪器,烟气分析系统,
北京市北斗星科技有限公司 电话: 010-6257.3917; 8264.0229; Fax: 010-8264.0221;
通信: 北京市603信箱
北斗星工化 100190 Web: http://www.big-dipper.cn/
锅炉执行 |
GB13271-91 《锅炉大气污染物排放标准》 |
pSMOKE-Boiler |
烟尘排放浓度:50-350/20000(mg/m3) 烟气黑度: 1(林格曼黑度,级) SO2排放浓度:100-1200(mg/m3) NOx排放浓度:400(mg/m3) 过量空气系数:1.2-1.8 |
工业炉窑 |
GB9078-1996 《工业炉窑大气污染物排放标准》 |
pSMOKE-Stove |
烟尘排放浓度:100/5-500 (mg/m3) 烟气黑度: 1(林格曼黑度,级) SO2排放浓度:850,2000,4300(mg/m3) F-:6-50 mg/M3 过量空气系数:1.7,2.5,4.0 |
火电厂执行 |
GB13223-1996 《火电厂大气污染物排放标准》 |
pSMOKE-PP |
烟尘排放浓度:200/1000,800/3300 (mg/m3) 烟气黑度: 1(林格曼黑度,级) SO2排放浓度:1200,2100 (mg/m3) NOx排放浓度:650,1000(mg/m3) |
炼焦炉执行 |
GB16171-1996 《炼焦炉大气污染物排放标准》 |
pSMOKE-Coke |
颗粒物浓度:1.0-5.0,100/350,250/300(mg/m3) 烟气黑度: 1(林格曼黑度,级) SO2排放浓度:240-600,400/450(mg/m3) 苯可溶物(BSO):0.25-1.20(mg/m3) 笨丙[a]芘(B[a]P):0.0010, 0.0055,1.0/3.0,1.5/2.0(mg/m3) |
水泥厂 |
GB4915-1996 《水泥厂大气污染物排放标准》 |
pSMOKE-Cement |
烟尘或粉尘浓度:1.0/4.0,100/150,150/400,200/600(mg/m3) SO2排放浓度:300-800(mg/m3) F2/F-10/20,50/100 mg/M3 NOx排放浓度:200/400,800/1600(mg/m3) |
汽车排放 |
GB14761.1~14761.7-93 《汽车大气污染物排放标准》 |
pSMOKE-Auto |
|
|
GB14761.1-93 《轻型汽车排气污染物排放标准》 |
pSMOKE-Auto.1 |
排气污染得指汽车排气管排出的 一氧化碳(CO):65 碳氢化合物(HC):10.8-17.3(C6) 氮氧化物(NOx):8.5-13.6(NO2) |
|
GB14761.2-93 《车用汽油机排气污染物排放标准》 |
pSMOKE-Auto.2 |
排气污染得指汽车排气管排出的 一氧化碳(CO):34 碳氢化合物(HC):14-22 氮氧化物(NOx):14-22.氮氧化物以二氧化氮(NO2)当量表示, |
|
GB14761.3-93 《汽油车燃油蒸发污染物排放标准》 |
pSMOKE-Auto.3 |
VOC:2 |
|
GB14761.4-93 《汽油曲轴箱污染物排放标准》 |
pSMOKE-Auto.4 |
VOC定量:从通风管和PCV阀或计量孔得的复合流量经修正后大于漏气量, 定性:汽车运行 |
|
GB14761.5-93 《汽油车怠速污染物排放标准》 |
pSMOKE-Auto.5 |
HCU/V :700-8000(mg·L-1) CO:3.0-4.5% |
|
GB14761.6-93 《柴油车自由加速烟度排放标准》 |
pSMOKE-Auto.6 |
烟度<=Rb3.5-5.0 |
|
GB14761.7-93 《汽车柴油机全负荷烟度排放标准》 |
pSMOKE-Auto.7 |
烟度值 FSN:4.0-4.5 |
摩托车排气 |
GB14621-93 《摩托车排气污染物排放标准》 |
pSMOKE-MTC |
排气污染得指汽车排气管排出的 一氧化碳(CO):16 碳氢化合物(HC):7-21(C6) g/km;1200-9000ppm 氮氧化物(NOx):(NO2) |
北京北斗星科技有限公司
业务热线:010-6257.3917-806(环境气体分析/污染源监测);email: sales@big-dipper.us sales@bigdipper-technochem.com